EC0X TEMPERATURE CHAMBER
The EC0X series of environmental chambers feature the TC01 controller which allows for local and remote temperature, time, and cycling control. Built in IEEE-488 (GPIB), RS232/RS422 remote interfaces are standard features on the EC0X temperature chamber and are available in sizes ranging from .37 cu ft. to 3.0 cu ft of working volume. These chambers use vertical air flow with convection style heating and have a temperature range from -100°C to 300°C (using LN2) or -73°C to 300°C (using LCO2). These temperature chambers may be equipped with options such as 1" to 4" circular ports, shelves, electronic failsafe and window doors.
| Model | EC0A (pdf) | EC01 (pdf) | EC02 (pdf) | EC03 (pdf) |
| Working Volume | .37 ft3 |
.7 ft3 |
2.2 ft3 |
3.0 ft3 |
| Work space dimensions [inches(centimeters)] | 10.0 (25.4) W 8.0 (20.3) H 8.0 (20.3) D |
12.0 (30.5) W 9.75 (24.75) H 10.25 (26.0) D |
20.0 (50.8) W 12.0 (30.5) H 16.0 (40.6) D |
20.0 (50.8) W 12.0 (30.5) H 22.0 (40.6) D |
| Overall dimensions [inches(centimeters)] | 17.5 (44.5) W 13.25 (33.7) H 20.0 (50.8) D |
21.0 (53.3) W 16.0 (40.6) H 24.0 (61.0) D |
30.0 (76.2) W 19.5 (49.5) H 30.0 (76.2) D |
30.0 (76.2) W 19.5 (49.5) H 36.0 (91.4) D |
| Max Heat/Cool Rate | .5ºC/sec (30ºC/min) |
.5ºC/sec (30ºC/min) |
.25ºC/sec (15ºC/min) |
.25ºC/sec (15ºC/min) |
| Air-Flow (CFM, Vertical) | 60 ft3/min | 60 ft3/min | 150 ft3/min | 300 ft3/min |
Power Option 110VAC 50/60 Hz |
YES | YES | YES | NO |
| Power Option 208/220VAC, 50/60Hz Single Phase, 3/4 Wire |
YES | YES | YES | YES |
Power Option 240 VAC, 50 Hz |
YES | YES | YES | YES |
| Power Requirement | 1600 Watts | 1800 Watts | 2200 Watts | 3000 Watts |
| Weight; Net/Shipping | 38/55 lbs | 49/68 lbs | 80/100 lbs | 98/115 lbs |
| Expendable Gas Coolant Usage LCO2 @ 0°C |
1.8 lbs/hr | 2 lbs/hr | 3.5 lbs/hr | 5 lbs/hr |
| Expendable Gas Coolant Usage LCO2 @ -55°C |
4 lbs/hr | 6 lbs/hr | 11 lbs/hr | 15 lbs/hr |
| Expendable Gas Coolant Usage LN2 @ 0°C |
.7 lbs/hr | 1 lbs/hr | 2 lbs/hr | 2.5 lbs/hr |
| Expendable Gas Coolant Usage LN2 @ -55°C |
2.2 lbs/hr | 3 lbs/hr | 5.5 lbs/hr | 7.5 lbs/hr |
| CONTROLLER SECTION (included in chamber cost) |
MODEL TC01 (also available for retrofit) |
|||
| Temperature Set Point Range | -73ºC to +300ºC in 0.1º Steps (LN2 Option; -100ºC to +300ºC) | |||
| Time at Temperature Range | 0.1 to 1800 minutes or Continuous (Optionally, 0.1 to 1800 hours) | |||
| Temperature Ramping Rate Control | Not Controlled Locally | |||
| Programmable Set Temps and Times | 10 Programmable Set Temperatures and Times | |||
| Absolute Error (not including probe error) | ±0.4ºC | |||
| Long Term Stability (per month) | ±0.3ºC | |||
| Temperature Resolution | 0.1ºC | |||
| Line Voltage Sensitivity (105-125 VAC) | ±0.2ºC | |||
| Programmable Temperature Loop Control | 1 to 1800 Cycles of Programmable Set Temperatures and Set Times or Continuous | |||
| Temperature Control Technique | PID Algorithm / Pulse Width Modulated, Programmable from Remote Interfaces | |||
| Local Operation | 16 Key Keyboard / 4 Digit Display | |||
| Remote Operation | Built-in IEEE-488 / RS232 Interfaces | |||
| Additional I/O Capability | IEEE-488 to RS232 Transparent Mode, 2 Auxiliary Outputs, 1 Auxiliary Input | |||
| Safety Features | Open/Short Probe Detection, Adjustable Over Temperature Thermostat, Software Upper Temperature Limit | |||
| Convenience Features | Heat and Cool Enable/Disable Switches | |||